Magmeter Flow Sensor (FLS F6.60) Graphics

MAGMETER FLOW SENSOR - FLS F6.60

The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.
The F6.60 family can provide three different options: frequency output to be connected to FLS flow monitors, 4-20 mA output for long distance transmission and PLC connection and the new volume pulse output freely settable.

The insertion magmeter family is provided with an USB interface and a dedicated software (freely downloadable from FLS web site) which allows to easily set by a PC all parameters according to specific installation requirements (as full scale and cut off).

The specific design allows an accurate flow measurement over a wide dynamic range in pipe sizes from DN15 (0.5”) to DN600 (24”).

Key Features of FLS F6.60

No moving parts, no wear, maintenance free

High mechanical resistance

High mechanical resistance

Accurate measurement of dirty liquids

Pipe size range: from DN15 (0,5”) to DN600 (24”)

Adjustable Flow Rate Range

Low pressure drop

User Settable Operating Parameters

4-20 mA, frequency or volumetric pulse output

Bi-directional flow measurement selectable (for F6.60)

Special versions for salt-water applications (high concentrations of chlorides like sea water) and for high temperature conditions

Technical Information

General

Specification Details
Pipe Size Range
DN15 to DN600 (0.5” to 24”)
Max Flow Rate Range (F6.60)
0.05 to 8 m/s
Max Flow Rate Range (F6.63)
0.15 to 8 m/s
Full Scale
8 m/s (26.24 ft/s)
Linearity
± 1% of reading + 1.0 cm/s
Repeatability
± 0.5% of reading
Enclosure
IP65 front
Materials (case)
ABS
Wetted Materials
Sensor body: 316L SS/PVDF; 316L SS/PEEK; CuNi alloy/PVDF
o-rings
EPDM or FPM
Electrodes
316L SS or CuNi alloy

Electrical

Parameter Details
Power Supply
12 to 24 VDC ± 10% regulated (reverse polarity and short circuit protected)
Max Current Consumption
250 mA
Protective Earth
< 10 Ω
Current Output
4-20 mA, isolated
Max Loop Impedance
800 Ω @ 24 VDC – 250 Ω @ 12 VDC
Flow Indication
Positive or negative
Solid State Relay Output
User selectable as MIN alarm, MAX alarm, Volumetric, Pulse Out, Window alarm
Relay Output Specs
Optically isolated, 50 mA MAX sink, 24 VDC MAX pull-up voltage
Max Pulse/min
300
Hysteresis
User selectable
Open Collector Output (Frequency)
Type: Open Collector NPN, Frequency: 0–800 Hz
Open Collector Output Specs
Max pull-up voltage: 24 VDC, Max current: 50 mA, Compatible with M9.02, M9.50, M9.07, M9.08, M9.10
Flow Direction
0 VDC arrow-wise, +VDC anti arrow-wise

Environmental

Specifications Details
Storage Temperature
-30°C to +80°C (-22°F to +176°F)
Ambient Temperature
-20°C to +70°C (-4°F to +158°F)
Relative Humidity
0 to 95% not condensing
Fluid Conditions
Homogeneous liquids, pastes or slurries, also with solid content
Min Electrical Conductivity
20 μS/cm
Temperature (PVDF bottom)
-10°C to +60°C (14°F to 140°F)
Temperature (PEEK bottom)
-10°C to +150°C (14°F to 302°F)
Max Operating Pressure
16 bar @ 25°C (232 psi @ 77°F), 8.6 bar @ 60°C (124 psi @ 140°F)

Standards & Approvals

Standard Details
Certifications
ISO 9001, ISO 14001, CE, RoHS Compliant, EAC