DUAL-PARAMETER CONDUCTIVITY AND FLOW MONITOR & TRANSMITTER (FLS M9.07) Graphics

DUAL-PARAMETER CONDUCTIVITY AND FLOW MONITOR & TRANSMITTER - FLS M9.07

The new FLS M9.07 is a dual monitor and transmitter which combines conductivity and flow measurements. A 4” wide full graphic display shows measured values clearly together with many other useful information. Moreover, due to a multicolor display plus a powerful backlight, measurement status can be determined easily from afar also. A tutorial software guarantees a mistake-proof and fast set up of every parameters. Different type of calibrations can be performed to fit user needs for both measurements. A 4-20mA output dedicated to each measurement grants to remote values to a external device. A proper combination of digital outputs allows customized setups for any process to be controlled. The USB port on the rear part allows the upgrade of software offering a wide range of customization services both standard and on request.

Key Features of FLS M9.07

Wide full graphic display

Multicolor backlight

Help on board

Simultaneous measurement of conductivity, temperature and flow

Fast, intuitive and mistake-proof calibration software

Mechanical relay for external device control

Solid State Relays for programmable alarms

Multilanguage menus

USB port for software upgrading

Technical Information

General

Parameter Details
Associated sensors
FLS conductivity/temperature sensors & FLS hall effect flow sensors with frequency output or FLS F6.60 Flow sensor magmeters
Materials
– case: ABS – display window: PC – panel & wall gasket: silicone rubber – keypad: 5-button silicone rubber
Display
LC full graphic display
Backlight version
3-colours
Backlight activation
User adjustable with 5 levels of timing
Update rate
1 second
Enclosure
IP65 front
Conductivity input range
0.055÷200000µS/cm (according to the cell constant applied)
Conductivity measurement accuracy
± 2.0 % of reading value
Temperature input range
-50÷150°C (-58÷302°F) (with Pt100-Pt1000)
Temperature measurement resolution
0.1°C/°F (Pt1000); 0.5°C/°F (Pt100)
Flow input range (frequency)
0÷1500Hz
Flow input accuracy (frequency)
0,5%

Electrical

Parameter Details
Supply Voltage
12 to 24 VDC ± 10% regulated
Max Power Consumption
<300mA
FLS hall effect Flow Sensor power
5 VDC @ < 20 mA
Isolation
Optically isolated from current loop
Short Circuit Protection
Yes
2* Current output
4-20 mA, isolated, fully adjustable and reversible
Max loop impedance
800 Ω @ 24 VDC – 250 Ω @ 12 VDC

Relay Outputs

Output Type Details
2* Solid State Relay output
– (Flow) user selectable as MIN alarm, MAX alarm, Pulse Out, Window alarm, Off – (Conductivity) user selectable as ON-OFF, Proportional frequency output, Timed Pulse, Off – Optically isolated, 50 mA MAX sink, 24 VDC MAX pull-up voltage – Max pulse/min: 300 – Hysteresis: user selectable
2* Relay output
– (Flow) user selectable as MIN alarm, MAX alarm, Pulse Out, Window alarm, Off – (Conductivity) user selectable as ON-OFF, Proportional frequency output, Timed Pulse, Off – Mechanical SPDT contact – Expected mechanical life (min. operations): 10⁷ – Expected electrical life (min. operations): 10⁵ N.O./N.C. switching capacity 5A/240VAC – Max pulse/min: 60 – Hysteresis: user selectable

Environmental

Parameter Details
Operating Temperature
-10 to +70°C (+14 to +158°F)
Storage Temperature
-30 to +80°C (-22 to +176°F)
Relative Humidity
0 to 95% not condensing

Standards & Approvals

Standard Status
ISO 9001
Manufactured under ISO 9001
ISO 14001
Manufactured under ISO 14001
CE
Certified
RoHS Compliant
Yes
EAC
Yes