Ultra Low Flow Sensor (FLS ULF) Graphics

ULTRA LOW FLOW SENSOR - FLS ULF

The FLS compact Ultra Low Flow sensors ULF have been for use with every kind of aggressive and solid-free liquids.
The sensor can be fixed to flexible or rigid pipes via 1/4” GAS threaded process connections. The paddlewheel sensor produces a frequency output proportional to the flow velocity that can be easily transmitted and processed.
The ULF sensor offers two different flow ranges starting from 1.5 or 6 l/h (0.0066 or 0.0264 gpm). The construction materials, POM or ECTFE (Halar®), provide high strength and chemical resistance.

Key Features of FLS ULF

POM or ECTFE (Halar®) wetted parts

Two flow ranges available:

1.5 - 100 l/h (0.0066 - 0.44 gpm)

6 - 250 l/h (0.0264 - 1.1 gpm)

High chemical resistance

Easy mounting

Technical Information

General

Parameter Details
Flow Rate Range
– ULF01 version: 1.5 to 100 l/h (0.0066 to 0.44 gpm)
– ULF03 version: 6 to 250 l/h (0.0264 to 1.1 gpm)
Linearity
± 1 % of full scale
Repeatability
± 0.5 % of full scale
Working Temperature
-10°C to 80°C (14°F to 176°F)
Working Pressure
5 bar (70 psi) max @ 22°C (72°F)
Viscosity of fluid
1 to 10 cST
Enclosure
IP65 front
Wetted materials (POM version)
Sensor body: POM O-ring: FPM Rotor: POM Shaft: Corepoint magnets SmCo₅
Wetted materials (ECTFE version)
Sensor body: ECTFE (Halar®) O-ring: FPM or KALREZ Rotor: ECTFE (Halar®) Shaft: Sapphire Bearings: Sapphire
Connections
1/4” GAS male threaded
Cable length
2 m (6.5 ft) standard

Specific for ULF01.H I and ULF03.H

Parameter Details
Supply Voltage
5 to 24 VDC ±10%, regulated
Supply current
< 15 mA @ 24 VDC
Output signal
Square wave
Signal type
Push-Pull (for connection to NPN and PNP inputs)
K-factor
– ULF01 version: 8431 Pulses/Liter (31569 Pulses/U.S. Gallon) in linear range from 8 to 100 l/h
– ULF03 version: 3394 Pulses/Liter (12846 Pulses/U.S. Gallon) in linear range from 15 to 250 l/h
2* Current output
4-20 mA, isolated, fully adjustable and reversible
Max loop impedance
800 Ω @ 24 VDC – 250 Ω @ 12 VDC

Specific for ULF01.R I and ULF03.R

sPECIFICATION Details
Supply voltage
None
Output signal
Square wave
Output type
Reed Contact
K-factor
– ULF01 version: 2108 Pulses/Liter (7978 Pulses/U.S. Gallon) in linear range from 8 to 100 l/h
– ULF03 version: 848 Pulses/Liter (3210 Pulses/U.S. Gallon) in linear range from 15 to 250 l/h

Standards & Approvals

Specification Details
Manufactured under
ISO 9001, ISO 14001
Certifications
CE, RoHS Compliant