ULTRA LOW FLOW SENSOR – FLS ULF
The FLS compact Ultra Low Flow sensors ULF have been for use with every kind of aggressive and solid-free liquids. The sensor can be fixed to flexible or rigid pipes via1/4” GAS threaded process connections. The paddlewheel sensor produces a frequency output proportional to the flow velocity that can be easily transmitted and processed. The ULF sensor offers two different flow ranges starting from 1.5 or 6 l/h (0.0066 or0.0264 gpm). The construction materials, POM or ECTFE(Halar®), provide high strength and chemical resistance.
Flow Measurement System
Flow Measurement System
APPLICATIONS
• Water treatment
• Chemical industry
• Pharmaceutical industry
• Dosing systems
• Laboratory plants
MAIN FEATURES
• POM or ECTFE (Halar®) wetted parts
• Two flow ranges available:
– 1.5 – 100 l/h (0.0066 – 0.44 gpm)
– 6 – 250 l/h (0.0264 – 1.1 gpm)
• High chemical resistance
• Easy mounting
Technical Data
General
• Flow Rate Range:
– ULF01 version: 1.5 to 100 l/h (0.0066 to 0.44 gpm)
– ULF03 version: 6 to 250 l/h (0.0264 to 1.1 gpm)
• Linearity: ± 1 % of full scale
• Repeatability: ± 0.5 % of full scale
• Working Temperature: -10°C to 80°C (14°F to 176°F)
• Working Pressure: 5 bar (70 psi) max @ 22°C (72°F)
• Viscosity of fluid: 1 to 10 cST
• Enclosure: IP65
• Wetted materials:
– POM version:
sensor body: POM
o-ring: FPM
rotor: POM
shaft: corepoint
magnets: SmCo5
– ECTFE version:
sensor Body: ECTFE(Halar®)
o-ring: FPM or KALREZ
rotor: ECTFE (Halar®)
shaft: Sapphire
bearings: Sapphire
• Connections: 1/4” GAS male threaded
• Cable length: 2 m (6.5 ft) standard
Specific for ULF01.H I and ULF03.H
• Supply voltage: 5 to 24 VDC ±10%, regulated
• Supply current: < 15 mA @ 24 VDC
• Output signal: square wave
• Signal type: Push-Pull (for connection to NPN and
PNP inputs)
• K-factor:
– ULF01 version: 8431 Pulses/Liter (31569 Pulses/
U.S. Gallon) in linear range from 8 to 100 l/h
– ULF03 version: 3394 Pulses/Liter (12846 Pulses/
U.S. Gallon) in linear range from 15 to 250 l/h
Pressure Drop
1 Electrical cable: 2 m. (6.5 ft) standard
2 Completely encapsulated electronics
3 Connection (other versions available
on request according to body material)
4 POM or ECTFE Halar® (registered
trademark of Ausimont-Solvay) sensor
body
5 PP fixing plate
WIRING CONNECTIONS
ULFXX.H Sensor wiring connection
ULFXX.R Sensor wiring connection
Wiring connections of ULFXX.H to the other monitors
M9.50 | M9.03 | M9.07 | M9.08 | M9.10 | ||
---|---|---|---|---|---|---|
GND | 30 | 30 | 16 | 16 | 16 | 37 |
IN | 28 | 28 | 14 | 14 | 14 | 36 |
V+ | 27 | 27 | 13 | 13 | 13 | 35 |
GET THE LATEST FLS ULF PRICES ON YOUR EMAIL