PADDLEWHEEL FLOW TRANSMITTER – FLS F6.30
The new FLS F6.30 is a blind transmitter based on paddlewheel. It can be applied for the measurement of every kind of solid-free liquids. TheF6.30 can provides different output options using a 4-20mA and a Solid State Relay. Analog output can be used for long distance transmission and SSR can be set as an alarm oras a volumetric pulse output.F6.30 Paddlewheel Flow Transmitter is provided with an USB interface and a dedicated software (freely downloadable from FLS web site) which allows to easily calibrate instrument and to intuitively set outputs by a PC. The specific design allows an accurate flow measurement over a wide dynamic range in pipe sizes from DN15 (0.5”) toDN600 (24”).
Flow Measurement System
Flow Measurement System
APPLICATIONS
• Industrial water and wastewater treatment
• Cooling water systems
• Swimming pools
• Flow control and monitoring
• Water treatment
• Water regeneration plant
• Processing and manufacturing industry
• Water distribution
MAIN FEATURES
• High chemical resistance
• Pipe size range: from DN15 (0,5”) to DN600 (24”)
• Low pressure drop
• Friendly calibration procedure
• 4-20 mA, frequency or volumetric pulse output settable by USB
• SSR settable as alarm by laptop
Technical Data
General
• Pipe Size Range: DN15 to DN600 (0.5” to 24”)
Please refer to Installation Fittings section for more
details
• Flow Rate Range: 0.15 to 8 m/s (0.5 to 25 ft./s)
• Linearity: ± 0.75 % of full scale
• Repeatability: ± 0.5 % of full scale
• Minimum Reynolds Number Required: 4500
• Enclosure: IP65
• Wetted Materials:
– sensor Body: C-PVC, PVDF or 316L SS
– o-rings: EPDM or FPM
– rotor: ECTFE (Halar®)
– shaft: Ceramic (Al2
O3
)/ 316L SS (for metal sensors)
– bearings: Ceramic (Al2
O3
), none (for metal sensor)
Electrical
• Power Supply:
– 12 to 24 VDC ± 10% regulated (reverse polarity and
short circuit protected)
• Max Power Consumption: 150 mA
– protective earth: < 10 Ω
• 1*Current output:
– 4-20 mA, isolated
– max. loop impedance: 800 Ω @ 24 VDC – 250 Ω @
12 VDC
• 1*Solid State Relay output:
– user selectable as MIN alarm, MAX alarm,
Volumetric, Pulse Out, Window alarm, Off
– optically isolated, 50 mA MAX sink, 24 VDC MAX
pull-up voltage
– max pulse/min: 300
– hysteresis: User selectable
Maximum Operating Pressure / Temperature (25 years lifetime)
F6.30 Transmitter
• C-PVC body:
– 10 bar (145 psi) @ 25°C (77°F)
– 1,5 bar (22 psi) @ 80° C (176°F)
• PVDF body:
– 10 bar (145 psi) @ 25°C (77°F)
– 2,5 bar (36 psi) @ 100°C (212°F)
• SS body:
– 25 bar (363 psi) @ 100°C (212°F)
DIMENSIONS
A Sensor body
B F6.30 Paddlewheel Flow Transmitter
1 O-Ring (EPDM or FPM)
2 Sensor body C-PVC, PVDF, 316L SS
3 Halar Rotor, Ceramic shaft & bearings
(316L SS shaft for metal sensors)
4 Cable Gland
5 ABS cap for installation into fittings (SS
cap for metal sensors)
6 Electronic box
WIRING CONNECTIONS
Rear Terminal View
A Sensor body
B F6.30 Paddlewheel Flow Transmitter
1 O-Ring (EPDM or FPM)
2 Sensor body C-PVC, PVDF, 316L SS
3 Halar Rotor, Ceramic shaft & bearings
(316L SS shaft for metal sensors)
4 Cable Gland
5 ABS cap for installation into fittings (SS
cap for metal sensors)
6 Electronic box
GET THE LATEST FLS F6.30 PRICES ON YOUR EMAIL