HIGH PRESSURE PADDLEWHEEL FLOW SENSOR – FLS F3.20

FLS F3.20 is a paddlewheel flow sensor suitable for system at high pressure and at critical temperature. F3.20 is designed for use with every kind of solid-free liquids in compliance with chemical compatibilities of wetted materials. First quality materials used, as SS for body/shaft and Halar® for rotor, grant high mechanical performances and an appreciated reliability. Sensor needs a very limited maintenance and, in those cases, it’s easy to perform due to a 4 screws system and to a graphite flat gasket.F3.20 sensor is available for connection to FLS monitors and for PLC connection directly .SS weld on adapter is available for sensor installation on pipe range from 1 1⁄2” to 8”(DN40 to DN200).

APPLICATIONS

• Heat Exchangers
• Reverse osmosis
• Cooling systems
• HVAC systems (heating, ventilation and air conditioning)
• Boiler feedwater

MAIN FEATURES

• Working range up to 110 bar (1600 PSI)and up to 248°F (120 °C)
• Wide operating range (from 0,15 to 8 m/s)
• Just one sensor and one fitting for a wide range of pipe dimensions (from
1 1⁄2” to 8”)
• High linearity and repeatability
• Limited maintanance need and easy execution
• Available special version for direct connection to PLC

Technical Data

General

• Pipe Size Range: DN40 to DN200
(0.5 to 8 in). Refer to Installation Fittings section for
more details
• Flow Rate Range: 0.15 to 8 m/s (0.5 to 25 ft./s)
• Linearity: ± 0.75% of full scale
• Repeatability: ± 0.5% of full scale
• Pressure: 110 bar (1600 psi)
• Temperature: 120 °C (248 °F)
• Minimum Reynolds Number Required: 4500
• Enclosure: IP68
• Wetted Materials:
– sensor Body: 316L SS
– sealing system: graphite flat gasket
– rotor: ECTFE (Halar®)
– shaft: 316L SS

Specific for F3.20.H

• Supply voltage: 5 to 24 VDC regulated
• Supply current: < 30 mA @ 24 VDC
• Output signal:
– square wave
– frequency: 45 Hz per m/s nominal(13.7 Hz per ft/s
nominal)
– output type: transistor NPN open collector
– output current: 10 mA max
• Cable length: 8 m (26.4 ft) standard,300 m (990 ft)
maximum

Specific for F3.20.P

• Supply voltage: 12 to 24 VDC regulated
• Supply current: < 30 mA @ 24 VCC
• Output signal:
– square wave
– output frequency: 45 Hz per m/s nominal (13.7 Hz per
ft/s nominal)
– output type: Push – Pull (digital input NPN or PNP)
– output current: IOut max < 20 mA
• Cable length: 8 m (26.4 ft) standard,300 m (990 ft)
maximum

Standards & Approvals

• Manufactured under ISO 9001
• Manufactured under ISO 14001
• CE
• RoHS Compliant
• EAC

DIMENSIONS

1 Electrical cable: 8 m. (26.4 ft) standard
2 Graphite flat gasket
3 316L SS sensor body
4 ECTFE Halar® Open-cell rotor and
316L SS Shaft

WIRING CONNECTIONS

F3.20.H IP68 Sensor wiring connection

Standards & Approvals

• Manufactured under ISO 9001
• Manufactured under ISO 14001
• CE
• RoHS Compliant
• EAC

DIMENSIONS

1 Electrical cable: 8 m. (26.4 ft) standard
2 Graphite flat gasket
3 316L SS sensor body
4 ECTFE Halar® Open-cell rotor and
316L SS Shaft

Wiring connections to the other monitors

M9.00 M9.50 M9.03 M9.07 M9.08 M9.10
GND 7 30 30 16 16 16 37
IN 8 28 28 14 14 14 36
V+ 9 27 27 13 13 13 35

ORDERING DATA

Part No. Version Power supply Length Main Wetted Materials Enclosure Flow Rate Range Weight
F3.20.H.01 Hall 5- 24 VDC 107 mm 316L SS IP 68 0.15 to 8 m/s (0.5 to 25 ft./s) 600
F3.20.P.01 Push-Pull 12- 24 VDC 107 mm 316L SS IP 68 0.15 to 8 m/s (0.5 to 25 ft./s) 600